Why Is Water Dripping From the Outdoor Unit While Reverse-Cycle Heating Is Running?
Water dripping from the outdoor unit while your reverse-cycle system is heating is almost always normal. In heating mode the outdoor coil runs colder than the outside air, so moisture in that air condenses onto the coil and freezes into frost. The system then runs a short defrost cycle to melt that frost, and the meltwater drains out under the unit. A wet patch under the outdoor unit on a cold morning is usually the sign of a system working correctly.
We have looked after more than 35,000 customers at Heating Experts, and water pouring out of the outdoor unit is one of the most common things we get called about through winter. In the large majority of those jobs, nothing is wrong. The cases that do need a technician look different, and they are easy to recognise once you know what to compare.
Is Water Under the Outdoor Unit Normal in Winter?
Yes. Intermittent dripping or a damp patch under the outdoor unit during heating is expected behaviour for any reverse-cycle system, whether it is a split system or a ducted unit.
The confusing part is that most people meet their system in summer, when all the water appears indoors or at the end of a drain pipe. In winter the roles swap. The outdoor unit becomes the cold side of the system, so the outdoor unit is where the water forms. It is the same equipment running the reverse-cycle system in summer, and the water simply moves with it.
Where Does the Water Come From?
A reverse-cycle system moves heat from the outside air into your home rather than generating it, which is how it reaches 250 to 600 per cent efficiency according to the ACT Government buyers guide. That guide lists an average coefficient of performance of 3.5 for ducted reverse cycle and 5.0 for the best units, meaning 1 kW of electricity delivers 3.5 to 5 kW of heat.
There is more heat available outside than most people expect. Air at 0°C still holds over 90 per cent of the heat energy that air at 40°C holds. To pull that heat out, the refrigerant in the outdoor coil has to be colder than the outside air. When the coil surface drops below the dew point of the surrounding air, water vapour condenses onto the fins. When the coil also sits below 0°C, that moisture turns to frost.
So the water has two possible sources, and both are harmless:
- Condensation. Humid air touching a cold coil leaves liquid water behind, exactly as it does on a cold drink glass.
- Melted frost. Ice that formed on the coil turns back into water during the defrost cycle and drains away.
What Happens During a Defrost Cycle?
Frost on the coil blocks airflow and insulates the fins, so the system has to clear it. When sensors detect enough ice, the unit briefly reverses the refrigerant flow and sends hot gas out to the outdoor coil to melt it off.
Mitsubishi Electric Australia describes what you will notice: the indoor and outdoor fans stop so cold air is not blown into the house, while the compressor keeps running to melt the ice. The cycle continues until the coil reaches a high enough temperature, then heating resumes on its own. The same guidance is clear that defrosting is "not a fault with the product."
During that window you may see any of the following, all of them normal:
- Water running or dripping from the base of the outdoor unit
- A cloud of white vapour rising off the coil, which is melted frost evaporating
- The outdoor fan stopping while the unit still hums
- A brief hiss or whoosh as the reversing valve changes over
- Indoor air going cooler for a few minutes, or the system holding the fan off
Frost is worth clearing promptly because it costs real performance. In a 2024 laboratory study, researchers found that when 15%of the outdoor coil surface was iced, heating output fell by 11.2% and the coefficient of performance fell by 7.7%. At 35% coverage, the losses grew to 23.8% and 16.1%. The experimental findings on coil icing explain why manufacturers build defrost in rather than letting ice sit.
How Much Water Should You Expect to See?
More than most people assume. The ACT Government guide notes a reverse-cycle unit can produce up to several litres of condensate per hour, and all of it has to drain somewhere.
In practice, what we see on service calls is a steady trickle during and just after defrost, then nothing for 30 to 90 minutes until the next cycle. On a damp winter morning near 0°C, the drips can look constant. On a dry, cold day you may see almost nothing, because dry air leaves little moisture to condense in the first place.
The volume matters less than the pattern. Water that comes and goes with the heating cycle is defrosted. Water that runs continuously regardless of what the system is doing is worth investigating.
Normal Drainage vs a Fault: How to Tell the Difference
Use this table to work out which one you are looking at.
What you are seeing | Likely explanation | What to do |
Water dripping under the outdoor unit on and off during heating | Normal defrost meltwater draining away | Nothing. This is the correct operation. |
White vapour rising from the outdoor coil | Melted frost evaporating off a warm coil during defrost | Nothing. Vapour is white and odourless, and it fades within a metre or two. |
A light layer of frost on the coil before defrost runs | Normal frost build-up in cold, humid weather | Monitor. It should clear at the next defrost cycle. |
The coil encased in solid ice, or ice building under the unit | Restricted airflow, a dirty coil, a drainage problem, or low refrigerant | Book a service. Do not chip the ice off. |
Defrost running constantly, or cycles getting longer each time | Possible sensor, control board, sizing or installation fault | Book a service and note how often it cycles. |
The unit never defrosts and frost keeps building | Faulty defrost sensor or control | Turn the system off and call a technician. |
Water appearing inside the house or at the indoor unit | Blocked condensate drain or cracked drain pan. Not normal. | Turn the system off and arrange a repair. |
An oily residue rather than clear water | Possible refrigerant leak, as refrigerant escapes as gas and leaves oil behind | Call a licensed technician. Refrigerant work is not a DIY job. |
What Makes a System Defrost More Often Than Usual?
Some homes see a defrost cycle every half hour in July, others barely notice one. Mitsubishi Electric lists the main drivers, and they match what we find on site:
- Cold plus humidity. Damp mornings near freezing produce frost far faster than dry cold. Fog and heavy dew are the worst combination.
- Heavy heating demand. A thermostat set high keeps the compressor working hard, which keeps the coil cold for longer.
- Poor airflow around the outdoor unit. Enclosed courtyards, slat fencing, garden growth and tight alcoves trap cold, moist air against the coil.
- A unit mounted low to the ground. Cold, damp air pools at ground level.
- An undersized system. It runs longer to hit the same temperature, so it frosts more often.
- Dirty filters or coils. Restricted airflow drops coil temperature and accelerates frosting.
Insulation and draught sealing play a part too. A leaky home asks more of the system, and a system under constant load defrosts more. If your heater struggles to hold temperature at the same time as it defrosts frequently, look at zoning and airflow problems before blaming the outdoor unit.
Where Is Defrost Water Allowed to Drain?
This is where installation quality shows up. Australian plumbing rules require air conditioning condensate to be discharged to an approved outlet, with specific rules about where it can and cannot go.
The Victorian plumbing practice note MS 07 sets out acceptable discharge points, including a garden bed or a paved surface graded away from the building so ponding does not occur, a downpipe with the connection at least 300 mm below the indoor unit's drain outlet, or a sanitary drain via a tundish or self sealing device. It also states that discharging over the edge of a balcony where it will cause a nuisance is not acceptable, and that where defrost water could cause a nuisance on a balcony, the installer should provide a drained safe tray to collect the melted ice from the outdoor coil.
The same practice note covers the unit itself. Outdoor units should be mounted level on a suitable base or bracket, secured against movement, and installed with the manufacturer's ventilation clearance maintained behind the unit. A unit sitting flat on soil with no clearance gives meltwater nowhere to go, which is how you end up with an ice shelf under the coil.
When we are called out to drainage complaints at Heating Experts, the installation is the cause far more often than the equipment. A unit mounted hard against a fence, sitting at ground level, or draining onto a path will generate the same complaint every winter regardless of how good the system is.
Requirements vary between states, so check with your local plumbing regulator or ask your installer which rules apply to your address.
How to Stop Defrost Water Becoming a Hazard
Defrost water is only a problem when it collects where people walk. A few practical steps keep it harmless:
- Raise the unit. A stand or plinth with clear space underneath lets water drain away instead of pooling and refreezing.
- Lay a gravel bed underneath. Gravel absorbs the drip, stops splash-back onto the fins and prevents an ice sheet forming.
- Keep the discharge away from paths and doorways. Driveways, entry steps and footpaths are where a thin film of ice does damage.
- Grade the surface away from the house. Water sitting against brickwork or a slab edge causes slow, expensive damp problems.
- Clear leaves and garden growth. Debris blocks drainage holes in the base pan and restricts airflow, which worsens frosting.
- Never chip at ice on the coil. Mitsubishi Electric warns against chipping ice or pouring hot water on the unit, as both can damage the fins and refrigerant circuit.
What to Check Before Calling a Technician
If the amount of water looks excessive to you, run through these first:
- Watch a full cycle. Time how long the outdoor fan stays off and how long until heating resumes. Normal defrost finishes and heating returns on its own.
- Check the filters. Solar Victoria's home heating buyers guide recommends cleaning dust filters about twice a year, or more often if you run the system regularly. A clogged filter is the most common cause of poor airflow we find.
- Look at the outdoor unit's surroundings. Clear at least the manufacturer's stated clearance of plants, bins, boxes and stacked timber.
- Confirm where the water is going. Trace it. Water draining into a garden bed is fine. Water tracking back toward the house or across a path is not.
- Check indoors. Any water inside the home points to the condensate drain or drain pan, not the defrost cycle.
- Note any error codes. Write down whatever the controller displays before you call. It saves diagnostic time.
Noting the cycle timing and the filter condition before anyone attends makes diagnosis faster, because it rules out the two most common causes straight away. Most of these checks also form part of a standard pre-winter service.
When to Call a Licensed Technician
Book a service if you see any of the following:
- Ice that the defrost cycle cannot clear, or ice building up under the unit
- Defrost cycles that run constantly, or get longer every time
- A system that never defrosts while frost keeps accumulating
- Water inside the home, around the indoor unit, or at the ceiling below it
- An oily residue around the outdoor unit or on the pipework
- Heating that does not return to normal after defrost finishes
Two of these need prompt attention. Indoor water damages plaster and flooring quickly, and refrigerant work is restricted to licensed technicians under Australian law. Electrical work on these systems must also be carried out by a licensed electrician. If a system ices up repeatedly despite clean filters and clear airflow, it is worth working out whether repair or replacement makes better financial sense. Most heating units last about 15 to 20 years, so repeated faults on a system past 15 are worth costing out against a replacement.
Regular servicing and maintenance prevents most of the faults in that list. Clean coils, clean filters and clear airflow keep defrost cycles short and infrequent, which also keeps running costs down.
Frequently Asked Questions
Is the water under my outdoor unit refrigerant?
No. Refrigerant escapes as a gas and leaves an oily residue, not a clear puddle. Clear water under an outdoor unit during heating is condensate from the defrost cycle. An oily film is the sign worth calling about.
Why is steam coming off my outdoor unit in winter?
That is melted frost evaporating off a warm coil during defrost. It is white, odourless and disappears within a metre or two. Grey or dark smoke that smells like burning is a different matter, and the system should be switched off immediately.
Can I turn the heater off during a defrost cycle?
Let it finish. Interrupting a defrost cycle leaves ice on the coil, so the system starts its next heating run already restricted. If you need to shut down, wait until heating has resumed.
How long should a defrost cycle last?
There is no fixed length. The cycle runs until the outdoor coil is warm enough to clear the ice, then heating resumes automatically. Cycles that keep getting longer, or never seem to finish, are worth a service call.
Why is my outdoor unit dripping when there is no frost on it?
Plain condensation. The coil only needs to be below the dew point of the outside air for moisture to collect on the fins, and it does not need to be below freezing. On mild, humid days you get water without ever seeing frost.
Does a dripping outdoor unit mean my system is inefficient?
Not on its own. Dripping during defrost is a sign the system is managing frost properly. Efficiency losses come from frost that stays on the coil, not from water draining off it. If you are weighing up what the system costs you to run, our comparison of gas versus reverse-cycle running costs breaks down the numbers.
The Pattern to Watch
Judge the water by its timing rather than its volume. Water that comes and goes with the heating cycle is defrost drainage and needs no action. Continuous water, solid ice on the coil, water inside the house or an oily residue all point to a fault worth diagnosing.
If your system is icing up heavily, defrosting constantly, or leaving water somewhere it should not be, book a technician on 1300 100 040. We offer same day bookings and a 100% workmanship guarantee, and our technicians diagnose the problem before any work starts, so you know what you are paying for.